TE180 - Advanced microprocessor control unit

 
 
WELDING CONTROL UNIT TE 180

TE 180 is a microprocessor welding control unit for single-phase resistance welders. The welding control unit is used to control the welder parts and, in particular, the thyristor regulating the welding current. It is possible to program and to store up 15 different welding programs. All the programs can be recalled directly from the keyboard and from an external source by means of a PLC. Each program can assume all the configurations included between the simplest 4 times cycle, up to the most complex one, which can include the slopes, the pulses, the postheating, the forging and the minimum and maximum current limits.


 

TE180 - Advanced microprocessor control unit

MAIN FEATURES
  • 15 welding programs selectable by keyboard and by an external device.
  • 16 programmable parameters
  • Control of 3 solenoid valves 24 Vdc 7,2 W Max with protected output against short circuit
  • Display of the welding current in kA
  • Counter of the performed welds
  • Output of endcycle with relay, also selectable as interlock
  • Minimum and maximum limit of the welding current for each program
  • Output signal for out-of-limits spots with relay
  • Automatic compensation against voltage drops
  • Restart key and outputs enabling under Watch-dog control
  • Serial communication by means of insulated RS-232 interface (optional)
  • Removable key for programming or for run.
  • Integrated ammeter with four different capacities to select (18,36,45,90 kA)
  • Key to select foot control or two hands control
  • Possibility to eliminate the autoretain of the start signal during the welding process
  • Self-adjustment to the network frequency 50/60 Hz

PROGRAMMABLE PARAMETERS

PARAMETER RANGE
1° SQUEEZE 01 - 99 cycles
SQUEEZE 00 - 99 cycles
FORGE DELAY 00 - 99 cycles
SLOPE UP 00 - 29 cycles
WELD TIME 1 01 - 99 cycles
CURRENT 1 01 - 99 %
COLD TIME 1 00 - 50 cycles
IMPULSE N. 01 - 09
SLOPE DOWN 00 - 29 cycles
COLD TIME 2 00 - 50 cycles
WELD TIME 2 00 - 99 cycles
CURRENT 2 00 - 99 %
HOLD TIME 01 - 99 cycles
OFF TIME 00 - 99 cycles
MIN. CURR. 0 - 90 kA
MAX. CURR. 0 - 90 kA
 