| Items 2131-2144
- Linear action spot and projection welders - 63-150 kVA
 |
MAIN WELDER FEATURES
- Built-in compressed air filter unit.
- Electrodes speed control valves, shock absorber for end of stroke and air discharge silencers assuring the minimum noise.
- Lubrication free pneumatic components to eliminates oil mist and to protect the environment.
- Cylinder with chrome plated stem for heavy duty works and long life; adjustable anti-rotation device.
- Cylinder with double stroke with key control.
- Water-cooled transformer, plates, electrode-holders and electrodes.
- Transformer with epoxy resin coated windings.
- TE180 microprocessor control unit. Phase shift welding current adjustment. Synchronous SCR contactor insulated from cooling water circuit with protection thermostat.
- Two stage electric foot control for clamping and welding pieces only if correctly positioned. The foot control is standard on spot welder models only (on request on projection models).
- Pre-setting for additional double stage electric foot connection for the direct recalling of welding program no.2 (not on welders equipped with option 2181).
- Two-hand safety control with timer for maximum safety, and removable key selector, standard on all models. The push-buttons of the two hand control are standard on projection models only (on request on spot welder models).
|
TECHNICAL DATA
ITEM |
2131 |
2132 |
2133 |
2134 |
2135 |
2136 |
2141 |
2142 |
2143 |
2144 |
Spot welder |
• |
- |
• |
- |
• |
- |
• |
- |
• |
- |
Projection welder |
- |
• |
- |
• |
- |
• |
- |
• |
- |
• |
Nominal power at 50% |
kVA |
63 |
63 |
80 |
80 |
100 |
100 |
125 |
125 |
150 |
150 |
Maximum welding power |
kVA |
195 |
230 |
255 |
295 |
355 |
405 |
405 |
465 |
465 |
535 |
Short circuit current |
kA |
34 |
40 |
38 |
44 |
44 |
50 |
48 |
55 |
50 |
58 |
Maximum welding current on aluminium |
kA |
30.9 |
36.4 |
34.5 |
40 |
40 |
45.5 |
43.6 |
50 |
45.5 |
52.7 |
Maximum welding current on steel |
kA |
27.2 |
32 |
30.4 |
35.2 |
35.2 |
40 |
38.4 |
44 |
40 |
46.4 |
Thermal current 100% |
A |
6200 |
6200 |
6800 |
6800 |
7000 |
7000 |
8400 |
8400 |
9200 |
9200 |
No load secondary voltages |
V |
7.1 |
7.1 |
8.3 |
8.3 |
10 |
10 |
10.5 |
10.5 |
11.5 |
11.5 |
|
V |
6.3 |
6.3 |
7.5 |
7.5 |
9 |
9 |
9 |
9 |
10.2 |
10.2 |
|
V |
5.6 |
5.6 |
6.7 |
6.7 |
8 |
8 |
8 |
8 |
9 |
9 |
|
V |
5 |
5 |
6.1 |
6.1 |
7.1 |
7.1 |
7.3 |
7.3 |
- |
- |
Supply voltage 50Hz * |
V |
400 |
400 |
400 |
400 |
400 |
400 |
400 |
400 |
400 |
400 |
Cables section L=30 m |
mm2 |
50 |
50 |
70 |
70 |
95 |
95 |
2x50 |
2x50 |
2x70 |
2x70 |
Delayed fuses |
A |
125 |
125 |
160 |
160 |
200 |
200 |
250 |
250 |
315 |
315 |
Minimum gap |
mm |
160 |
146 |
160 |
146 |
160 |
146 |
160 |
146 |
160 |
146 |
Maximum gap |
mm |
360 |
313 |
360 |
313 |
360 |
313 |
360 |
313 |
360 |
313 |
Depth L |
mm |
280 |
- |
280 |
- |
280 |
- |
280 |
- |
280 |
- |
Depth D |
mm |
- |
230 |
- |
230 |
- |
230 |
- |
230 |
- |
230 |
Max. electrode force (6 bar) - standard |
daN |
736 |
736 |
736 |
736 |
736 |
736 |
736 |
736 |
736 |
736 |
Max. electrode force (6 bar) with optional cilinder |
daN |
- |
1242 |
- |
1242 |
- |
1242 |
- |
1242 |
- |
1242 |
Maximum stroke |
mm |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
Double stroke - standard |
mm |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
Adjustable Double stroke (options 2184-2185) |
mm |
0-80 |
0-80 |
0-80 |
0-80 |
0-80 |
0-80 |
0-80 |
0-80 |
0-80 |
0-80 |
Compressed air supply |
bar |
6.5 |
6.5 |
6.5 |
6.5 |
6.5 |
6.5 |
6.5 |
6.5 |
6.5 |
6.5 |
Air for 1000 spots (6 bar) |
|
|
|
|
|
|
|
|
|
|
|
Standard version - stroke 20 mm |
Nm3 |
4.6 |
4.6 |
4.6 |
4.6 |
4.6 |
4.6 |
4.6 |
4.6 |
4.6 |
4.6 |
Standard version - max. stroke |
Nm3 |
15.4 |
15.4 |
15.4 |
15.4 |
15.4 |
15.4 |
15.4 |
15.4 |
15.4 |
15.4 |
With option 2183- stroke 20mm |
Nm3 |
- |
9.4 |
- |
9.4 |
- |
9.4 |
- |
9.4 |
- |
9.4 |
With option 2183- max. stroke |
Nm3 |
- |
21.7 |
- |
21.7 |
- |
21.7 |
- |
21.7 |
- |
21.7 |
Air supply hose |
mm |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
Water cooling |
l/min |
8 |
8 |
8 |
8 |
8 |
8 |
8 |
8 |
8 |
8 |
Aerial noise produced |
dB(A) |
72 |
< 70 |
74 |
< 70 |
74 |
< 70 |
75 |
< 70 |
75 |
< 70 |
Measure conditions |
|
|
|
|
|
|
|
|
|
|
|
working stroke |
mm |
20 |
50 |
20 |
50 |
20 |
50 |
20 |
50 |
20 |
50 |
welding time |
cycles |
7 |
12 |
7 |
12 |
5 |
10 |
6 |
11 |
7 |
13 |
welding current |
kA |
25.5 |
30 |
28.5 |
33 |
33 |
37.5 |
37 |
42 |
37 |
43 |
working rating in welds/min |
|
15 |
6 |
15 |
6 |
15 |
6 |
15 |
6 |
15 |
6 |
Net weight (approximately) |
kg |
295 |
315 |
305 |
325 |
340 |
360 |
350 |
370 |
365 |
375 |
* Different voltages and frequencies on request
OPTIONS:
- 2180 Constant current welding control unit item TE185.
- 2181 Rotary selector for recalling the welding programs on the front side of the welder (this disables the second welding foot control).
- 2183 Cylinder 1242 daN (125 mm diameter, double stage) total stroke 100 mm (only for projection machines items 2132-2134-2136-2142-2144).
- 2184 Adjustable double stroke for cylinder 736 daN (standard).
- 2185 Adjustable double stroke for cylinder 1242 daN (OPT. 2183).
- 2186 Low force squeeze for cylinders 736 daN (standard).
- 2187 Low force squeeze for cylinders 1242 daN (OPT. 2183).
Specifications subject to change without notice. |
|
Υποκατηγορίες:
| Slide Show |  |
Online Visitors | Online Επισκέπτες 5 |
Total Visitors | Μοναδικοί Επισκέπτες 83542 |
Total Visits | Επισκεψιμότητα 1150775 |
|
|